Add to Cart
Number | Name | Specification and Type | Manufacture | Quantity | Main Technological Indexes |
| Air Compressor Pry | ||||
| Screw air Compressor | G355 | Atlas-Copco | 1 Set | Rated Air Capacity:≥57Nm3/min Rated Pressure:0.8MPa Oil Content in Air:≤3ppm Air Temperature:≤Ambient Temperature +70-80℃ Cooling Method:Air Cooling Power Rating:355KW Driving Mode: External Dimension: 4174*2120*2500mm |
| Air Storage Tank | CG1/8 | TRUE GAS | 1 Set | Rated Pressure:0.8Mpa Volume: 1m3 Material:Carbon Steel |
| Air Handling | ||||
| Three Level Filters
| CF006 TF006 AF006 |
Italy ATS |
3 pieces | Rated Pressure:1.0Mpa Connection Mode:DN25 Rated Handling Flow:25 Nm3/min Air Quality After Filtration: Particulate≤0.01μm oil≤0.003ppm Filter Pressure Drop:≤0.2bar Filter of all levels of the configuration system shall be configured with timed electronic discharge valve and manual draining valve. |
| Refrigeration Dryer | HF-25 | TRUE GAS | 1Set | Rated Pressure:0.6-1.0MPa Rated Handling Flow:25Nm³/min Pressure Loss in the System:≤0.2bar Rated Inlet Air Temperature:≤50℃ Outlet Air Dew Point Temperature :3℃ Power Rating:4.5KW |
|
Connecting Pipeline and Valve | / | TRUE GAS | 1 Set | Structure:Seamless Steel Tubes for Liquid Service Material:Carbon Steel of High Quality |
| skid-mounted nitrogen generator | ||||
| Molecular Sieve | 3KT-172 | Japan | 1 Batch | Nitrogen Purity:≥99.9% Capacity:300Nm³/h Design Inlet Pressure:0.7Mpa Design Operating Temperature:45℃ Maximum Operating Temperature:65℃ |
| Absorption Tower | XF-300 | TRUE GAS | 1 Set | Working Pressure:0.7Mpa Material:Q235B Design Pressure:0.8Mpa |
| PLC | S7-200 | Siemens | 1 Set | Control Mode:PLC Control Operating Voltage:24VDC Output Form:Relay Output All Components are Imported, Assembled to a Full Set Domestically |
| Pneumatic Valve | DN65 DN40 | SKF | 10 Pieces 6pieces | Start Mode:Pneumatic Control Mode:Solenoid Valve Material: Stainless 304 |
| Solenoid Valve | 3v-210 | Taiwan AirTac | 8 Pieces | |
| Nitrogen Gas Analyzer | P860-5N | Chang Ai | 1Piece | Measuring Range:78%~99.99% Principle of Sensors: Ion Beam; Nitrogen Sensor Measuring Mode: Gas Inlet |
| Nitrogen Buffer Tank | CG1/8 | TRUE GAS | 2 Piece | Rated Pressure: 0.8Mpa Design Pressure: 0.84Mpa Volume: 1 m3 Material: Carbon Steel |
| Flow Meter | LZB-25 |
Changzhou Shuanghuan | 3Piece | Rated pressure:1.0Mpa Diameter:DN40 |
| Craft Manifold,Valve | / | TRUE GAS | 1 Set | Structure:Seamless Steel Tubes for Liquid Service Material:Carbon Steel of High Quality |
| Skid-mounted | / | TRUE GAS | 1Set | Structure: Steel Structure Base Material:Low-Carbon Steel |
| Nitrogen Storage Tank | CG5/8 | TRUE GAS | 1Piece | Rated Pressure:0.8Mpa Design Pressure:0.84Mpa Volume: 5m³ Material: Carbon Steel |
| Container | 20 feet | TRUE GAS | 3 sets | Material: Carbon steel |
| Other Auxiliaries | ||||
| Finished Documents | / | TRUE GAS | 1 Set | Complete Set of Equipment Data |
| Accessories | / | TRUE GAS | 1 Set | Original Supporting Equipment Accessories |
Technical Indicators |
Technical Indicators |
Nitrogen flow: 0-2,000Nm3/h O2: ≤1ppm Dew point: ≤-70℃ Nitrogen purity: 99.99%-99.999%
1. Good stability, oxygen content can be controlled to be less than 5ppm at any time.
2. High purity, capability of keeping long-term stability when nitrogen purity is 99.9995%.
3. High reliability, manufactured according to the international standard.